What are Hazardous Areas (Classified Locations)? [Required Flameproof Structures]

A hazardous area (classified location) is a location where flammable gases, vapors, or dusts may be present in sufficient quantity to pose an explosion or fire risk. Equipment used in these areas must meet specific flameproof or explosion-proof construction requirements.

>> Contact us about flameproof stirring equipment

Hazardous Area Classification

Hazardous areas are classified into zones based on the probability and duration of the presence of an explosive atmosphere:

ZoneDescription
Zone 0Explosive atmosphere present continuously or for long periods
Zone 1Explosive atmosphere likely to occur in normal operation
Zone 2Explosive atmosphere unlikely in normal operation; if it occurs, it will be infrequent and short-lived

For dust explosions: Zone 20 (continuous), Zone 21 (likely), Zone 22 (unlikely but possible).

Flameproof Enclosure (Ex d)

Flameproof enclosure (IEC/JIS designation “Ex d”) is a protection concept in which the electrical equipment is enclosed in a housing strong enough to withstand an internal explosion without transmitting the explosion to the surrounding explosive atmosphere.

Key requirements for flameproof enclosures:

  • The enclosure must withstand the pressure of an internal explosion
  • Flame gaps (joint clearances) must be designed to quench any escaping flame before it can ignite the external atmosphere
  • Certification is required from an approved testing body; in Japan, certified by the Technology Institute of Industrial Safety (TIIS)

HEIDON Flameproof Stirrer: Ex Series

The HEIDON Three-One Motor Ex Series is the first motor-driven, flameproof enclosure agitator in the Three-One Motor lineup. It is certified to Ex db IIB T4 Gb and is suitable for Zone 1 and Zone 2 hazardous areas.

Note: The flameproof enclosure certification for the Ex Series is valid only in Japan. Power supply: 100 V AC only.

Three-One Motor Ex Series — details

Related Products

Three-One Motor Ex Series

Three-One Motor Ex Series
Flameproof enclosure agitator for Zone 1/2

Air Motor Stirrer TYPE:40A

Air Motor Stirrer TYPE:40A
Pneumatic stirrer — no electrical power, safe in hazardous areas

Air Motor Stirrer TYPE:40Ah

Air Motor Stirrer TYPE:40Ah
High-torque pneumatic stirrer

Inquiries about Compact Stirrers

👉 Contact us

For catalog requests and product inquiries,
please contact us using the inquiry form.